← Study Library
Systematic review · 2013 · n=644
Strongcounts toward this tierOutcomes of osteochondral allograft transplantation in the knee
Chahal J, Gross AE, Gross C, et al. · Arthroscopy
Strongcounts toward this tier
86% patient satisfaction and 18% failure at mean 58 months; best outcomes in younger patients with unipolar traumatic or OCD lesions.
- Population
- 644 knees across 19 studies of osteochondral allograft transplantation
- Intervention
- Osteochondral allograft
- Comparator
- None (pooled)
- Limitations
- Level IV evidence pooled; heterogeneous graft storage, lesion types, and outcome measures.
Cited by
1 entry references this study
- Fresh osteochondral allograftPROM.
Treatments & Surgery → Scaffolds & grafts